{"product_id":"trolmaster-mbspar-quantum-sensor","title":"TrolMaster Full Spectrum Quantum Sensor (MBS-PAR) | Precision PPFD \u0026 Auto-Dimming Control","description":"\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe \u003cb data-path-to-node=\"10\" data-index-in-node=\"4\"\u003eTrolMaster Full Spectrum Quantum Sensor (MBS-PAR)\u003c\/b\u003e is a professional-grade solution for measuring Photosynthetically Active Radiation (PAR) from all modern grow light sources. Designed with an improved spectral response, this sensor excels at capturing accurate data from \u003cb data-path-to-node=\"10\" data-index-in-node=\"275\"\u003eLED, HID, and Fluorescent\u003c\/b\u003e systems within a range of \u003cb data-path-to-node=\"10\" data-index-in-node=\"327\"\u003e389 to 692 nm (± 5 nm)\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003eWhether you are a commercial cultivator or a dedicated hobbyist, the MBS-PAR removes the guesswork from lighting by providing real-time \u003cb data-path-to-node=\"11\" data-index-in-node=\"136\"\u003ePPFD (Photosynthetic Photon Flux Density)\u003c\/b\u003e readings, ensuring your plants receive the exact light intensity they need for every stage of growth.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eIntelligent Auto-Dimming Technology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"13\"\u003eWhen integrated with the \u003cb data-path-to-node=\"13\" data-index-in-node=\"25\"\u003eTrolMaster Hydro-X\u003c\/b\u003e controller, the MBS-PAR transforms from a simple meter into an active control device. The system can \u003cb data-path-to-node=\"13\" data-index-in-node=\"145\"\u003eAUTOMATICALLY\u003c\/b\u003e adjust the output levels of your supplemental lighting to maintain a consistent, user-defined PPFD level. This not only prevents light stress and bleaching but also maximizes energy efficiency by dimming lights when natural sunlight is present or when lamps are over-performing.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eFull-Spectrum Accuracy:\u003c\/b\u003e Optimized for modern LED spectral outputs, ensuring reliable readings across the 389–692nm range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eActive PPFD Management:\u003c\/b\u003e Works with the Hydro-X to increase or decrease light intensity automatically to hit your \"sweet spot.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCost-Effective Precision:\u003c\/b\u003e Provides research-grade PAR measurement at a fraction of the cost of handheld laboratory meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eSeamless Integration:\u003c\/b\u003e Easily daisy-chains with other TrolMaster sensors (Temp, Humidity, CO2) into your main controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eReal-Time Monitoring:\u003c\/b\u003e View live PAR levels directly on your controller screen or via the \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"89\"\u003eTM+ smartphone app\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"16\"\u003e\n\u003ch2 data-path-to-node=\"17\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable data-path-to-node=\"18\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,1,0,0\"\u003e\u003cb data-path-to-node=\"18,1,0,0\" data-index-in-node=\"0\"\u003eSpectral Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,1,1,0\"\u003e389 to 692 nm (± 5 nm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,2,0,0\"\u003e\u003cb data-path-to-node=\"18,2,0,0\" data-index-in-node=\"0\"\u003eMeasurement Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,2,1,0\"\u003ePPFD (Photosynthetic Photon Flux Density)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,3,0,0\"\u003e\u003cb data-path-to-node=\"18,3,0,0\" data-index-in-node=\"0\"\u003eCompatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,3,1,0\"\u003eHydro-X (HCS-1), Hydro-X Pro (HCS-2), Tent-X (TCS-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,4,0,0\"\u003e\u003cb data-path-to-node=\"18,4,0,0\" data-index-in-node=\"0\"\u003eConnection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,4,1,0\"\u003eRJ12 Daisy-Chain\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,5,0,0\"\u003e\u003cb data-path-to-node=\"18,5,0,0\" data-index-in-node=\"0\"\u003eAutomatic Control\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,5,1,0\"\u003eSupports Auto-Dimming via Controller Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-path-to-node=\"20\"\u003ePro Tips: Maintenance!\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"21\"\u003e\u003cb data-path-to-node=\"21\" data-index-in-node=\"0\"\u003eSensor Care \u0026amp; Longevity\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"22\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003e\u003cb data-path-to-node=\"22,0,0\" data-index-in-node=\"0\"\u003eStay Dry \u0026amp; Clean:\u003c\/b\u003e To prevent premature failure, the MBS-PAR must remain dry. Avoid spraying foliar feeds or pesticides near the sensor, and ensure it is positioned away from misting systems or humidifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003e\u003cb data-path-to-node=\"22,1,0\" data-index-in-node=\"0\"\u003eNo Condensation:\u003c\/b\u003e Monitor your environment to ensure water does not condense on the sensor lens, as this will refract light and lead to false, lower PPFD readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003e\u003cb data-path-to-node=\"22,2,0\" data-index-in-node=\"0\"\u003eCleaning the Lens:\u003c\/b\u003e If dust accumulates, gently clean the sensor's top surface with a dry, lint-free microfiber cloth. Do not use abrasive chemicals or rough materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"23\"\u003e\u003cb data-path-to-node=\"23\" data-index-in-node=\"0\"\u003eOptimizing Your Light Map\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"24\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,0,0\"\u003e\u003cb data-path-to-node=\"24,0,0\" data-index-in-node=\"0\"\u003ePlacement is Key:\u003c\/b\u003e Mount the MBS-PAR at the \u003cb data-path-to-node=\"24,0,0\" data-index-in-node=\"43\"\u003eaverage canopy height\u003c\/b\u003e and directly under a light fixture for a \"worst-case\" intensity reading, or at the edge of the footprint to find your minimum light levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,1,0\"\u003e\u003cb data-path-to-node=\"24,1,0\" data-index-in-node=\"0\"\u003eAvoid Shadows:\u003c\/b\u003e Ensure that tent poles, hanging wires, or tall fan leaves do not cast shadows over the sensor, as this will trigger the Auto-Dimming feature to ramp up your lights unnecessarily.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TrolMaster","offers":[{"title":"Default Title","offer_id":55628381520257,"sku":"TM-QUANTUM-SENSOR","price":530.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0565\/5370\/1536\/files\/trolmaster--quantum-par-sensor-MBS-PAR.jpg?v=1777993145","url":"https:\/\/steelroots.co.uk\/products\/trolmaster-mbspar-quantum-sensor","provider":"Steel Roots ","version":"1.0","type":"link"}