{"product_id":"trolmaster-4rs2-devise-station","title":"TrolMaster 4RS-2 Device Station Kit | 4-Outlet Universal Module for Tent-X Control","description":"\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe \u003cb data-path-to-node=\"10\" data-index-in-node=\"4\"\u003eTrolMaster 4RS-2\u003c\/b\u003e is the ultimate power management solution for growers using the \u003cb data-path-to-node=\"10\" data-index-in-node=\"85\"\u003eTent-X (TCS-1)\u003c\/b\u003e system. This universal 4-outlet device module kit acts as a central power hub, allowing you to connect and automate four separate pieces of equipment through a single, streamlined station. By connecting the 4RS-2 to your Tent-X via \u003cb data-path-to-node=\"10\" data-index-in-node=\"332\"\u003eRJ12 cables\u003c\/b\u003e, you instantly transform your \"dumb\" appliances into intelligent, sensor-driven components of your grow environment.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eHeavy-Duty Power \u0026amp; Smart Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eBuilt for high-performance grow rooms, each of the four outlets on the 4RS-2 is capable of providing up to \u003cb data-path-to-node=\"12\" data-index-in-node=\"107\"\u003e15A of power\u003c\/b\u003e, ensuring you can safely run energy-intensive devices like heaters, large dehumidifiers, or high-flow pumps. To simplify your setup, the kit comes with four pre-configured default outputs (ordered left to right):\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eDST x1 (Temperature):\u003c\/b\u003e For heaters or cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eDSH x1 (Humidity):\u003c\/b\u003e For humidifiers or dehumidifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eDSP x2 (Program\/Timer):\u003c\/b\u003e For irrigation pumps, light movers, or circulating fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eQuick \u0026amp; Easy Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"15\"\u003eThe 4RS-2 was designed with a \"plug-and-play\" philosophy. The main power cable connects directly to your wall socket, while the internal logic is handled by the Tent-X controller. This eliminates the need for complex electrical wiring or multiple individual plug-in modules cluttering your tent. It occupies the \u003cb data-path-to-node=\"15\" data-index-in-node=\"312\"\u003e4 device module slots\u003c\/b\u003e on your controller, providing a clean, professional, and centralized control point.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003e4-in-1 Power Hub:\u003c\/b\u003e Consolidates your climate and irrigation power needs into one durable station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eHigh Amperage Capacity:\u003c\/b\u003e Each output supports up to \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"51\"\u003e15A\u003c\/b\u003e, handling heavy hardware with ease.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eTent-X Synergy:\u003c\/b\u003e Seamlessly integrates with the TCS-1 to automate devices based on live sensor data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e\u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"0\"\u003ePre-Mapped Logic:\u003c\/b\u003e Defaulted to Temperature (DST), Humidity (DSH), and two Program (DSP) outlets for instant setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003e\u003cb data-path-to-node=\"17,4,0\" data-index-in-node=\"0\"\u003eReduced Cable Clutter:\u003c\/b\u003e Replaces four individual modules with one centralized RJ12 connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"18\"\u003e\n\u003ch2 data-path-to-node=\"19\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ctable data-path-to-node=\"20\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,1,0,0\"\u003e\u003cb data-path-to-node=\"20,1,0,0\" data-index-in-node=\"0\"\u003eCompatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,1,1,0\"\u003eTrolMaster Tent-X (TCS-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,2,0,0\"\u003e\u003cb data-path-to-node=\"20,2,0,0\" data-index-in-node=\"0\"\u003eOutlet Count\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,2,1,0\"\u003e4 Universal Outlets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,3,0,0\"\u003e\u003cb data-path-to-node=\"20,3,0,0\" data-index-in-node=\"0\"\u003eMax Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,3,1,0\"\u003e15A Per Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,4,0,0\"\u003e\u003cb data-path-to-node=\"20,4,0,0\" data-index-in-node=\"0\"\u003eDefault Configuration\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,4,1,0\"\u003e1x DST, 1x DSH, 2x DSP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,5,0,0\"\u003e\u003cb data-path-to-node=\"20,5,0,0\" data-index-in-node=\"0\"\u003eConnection Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"20,5,1,0\"\u003eRJ12 (Occupies 4 Device Slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-path-to-node=\"22\"\u003ePro Tips: Setup \u0026amp; Load Management\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"23\"\u003e\u003cb data-path-to-node=\"23\" data-index-in-node=\"0\"\u003eManaging Your Electrical Load\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"24\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,0,0\"\u003e\u003cb data-path-to-node=\"24,0,0\" data-index-in-node=\"0\"\u003eCheck Your Circuit:\u003c\/b\u003e While each outlet can handle 15A, ensure the main circuit breaker powering the 4RS-2 can support the \u003cb data-path-to-node=\"24,0,0\" data-index-in-node=\"121\"\u003ecombined wattage\u003c\/b\u003e of all four devices running simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,1,0\"\u003e\u003cb data-path-to-node=\"24,1,0\" data-index-in-node=\"0\"\u003eHeater \u0026amp; Dehumidifier Placement:\u003c\/b\u003e If using the DST outlet for a heater and the DSH outlet for a dehumidifier, ensure they aren't positioned directly next to each other, as the heat from one can \"trick\" the humidity sensor of the other.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"25\"\u003e\u003cb data-path-to-node=\"25\" data-index-in-node=\"0\"\u003eSafety \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003e\u003cb data-path-to-node=\"26,0,0\" data-index-in-node=\"0\"\u003eCable Routing:\u003c\/b\u003e Keep your RJ12 data cables separated from the high-voltage power cables where possible to prevent any electromagnetic interference (EMI) that could affect the digital signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003e\u003cb data-path-to-node=\"26,1,0\" data-index-in-node=\"0\"\u003eFirmware Verification:\u003c\/b\u003e Ensure your Tent-X is recognizing all four modules. If an outlet isn't responding, check the \"Device List\" on your controller to ensure the 4RS-2 is properly addressed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TrolMaster","offers":[{"title":"Default Title","offer_id":55628381585793,"sku":"TM-4-RS2-DS","price":244.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0565\/5370\/1536\/files\/trolmaster-4rs-devise-dock-station-1.png?v=1777994598","url":"https:\/\/steelroots.co.uk\/products\/trolmaster-4rs2-devise-station","provider":"Steel Roots ","version":"1.0","type":"link"}