{"product_id":"ram-airtech-lite-carbon-filter","title":"RAM AirTECH LITE Carbon Filter – 4″, 5″, 6″ \u0026 8″","description":"\u003ch2\u003eRAM Activated Carbon Filters for Grow Room Odour Control\u003c\/h2\u003e\n\u003cp\u003eThe RAM AirTECH LITE Carbon Filter is designed to remove unwanted airborne odours from indoor growing and horticultural environments. Available with 100 mm, 125 mm, 150 mm and 200 mm connection sizes, the range supports extraction airflow rates from 250 m³\/h to 900 m³\/h.\u003c\/p\u003e\n\u003cp\u003eEach filter contains premium Australian activated carbon that is machine-compacted to create a dense and consistent carbon bed. This construction helps reduce gaps through which untreated air could otherwise pass, supporting effective filtration across the filter’s rated airflow.\u003c\/p\u003e\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eActivated carbon filter for indoor grow room odour control\u003c\/li\u003e\n\u003cli\u003ePremium Australian activated carbon\u003c\/li\u003e\n\u003cli\u003eMachine-compacted carbon bed helps minimise unfiltered air bypass\u003c\/li\u003e\n\u003cli\u003eAvailable in 4-inch, 5-inch, 6-inch and 8-inch connection sizes\u003c\/li\u003e\n\u003cli\u003eRated airflow options from 250 m³\/h to 900 m³\/h\u003c\/li\u003e\n\u003cli\u003eZintec-coated steel top and base provide structural strength\u003c\/li\u003e\n\u003cli\u003eInternal vortex cone promotes smoother airflow through the filter\u003c\/li\u003e\n\u003cli\u003eSilicone filter bands help prevent fine dust from reaching the carbon core\u003c\/li\u003e\n\u003cli\u003eRemovable and washable pre-filter sleeve included\u003c\/li\u003e\n\u003cli\u003eDesigned for connection to a compatible inline extraction fan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMachine-Compacted Australian Activated Carbon\u003c\/h3\u003e\n\u003cp\u003eThe AirTECH LITE uses activated carbon manufactured from Australian raw material. The carbon is compacted mechanically to maximise density and reduce gaps within the carbon bed.\u003c\/p\u003e\n\u003cp\u003eAs extracted air passes through the filter, odour-producing compounds are adsorbed onto the internal surface of the activated carbon. The filter should always be matched with an extraction fan operating within its published airflow rating.\u003c\/p\u003e\n\u003ch3\u003eReinforced Filter Construction\u003c\/h3\u003e\n\u003cp\u003eThe top and base are manufactured from Zintec-coated steel to reinforce the filter body. An internal vortex cone directs airflow through the carbon bed, while silicone sealing bands help stop carbon dust and fine particles from escaping into the ventilation system.\u003c\/p\u003e\n\u003cp\u003eA removable fabric pre-filter surrounds the main body. This sleeve captures larger airborne particles before they reach the activated carbon and can be removed for routine cleaning.\u003c\/p\u003e\n\u003ch3\u003eAvailable Sizes and Airflow Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVariant\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eBody length\u003c\/th\u003e\n\u003cth\u003eMaximum rated airflow\u003c\/th\u003e\n\u003cth\u003eRAM product code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-inch filter\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003ctd\u003e250 m³\/h\u003c\/td\u003e\n\u003ctd\u003e08-350-335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5-inch filter\u003c\/td\u003e\n\u003ctd\u003e125 mm\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003ctd\u003e350 m³\/h\u003c\/td\u003e\n\u003ctd\u003e08-350-340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6-inch filter\u003c\/td\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003ctd\u003e600 m³\/h\u003c\/td\u003e\n\u003ctd\u003e08-350-345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8-inch filter\u003c\/td\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003ctd\u003e900 m³\/h\u003c\/td\u003e\n\u003ctd\u003e08-350-355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChoosing the Correct Filter\u003c\/h3\u003e\n\u003cp\u003eSelect a filter with a connection diameter matching the extraction fan and ducting. The fan’s working airflow should not exceed the filter’s maximum published rating.\u003c\/p\u003e\n\u003cp\u003eActual airflow can be reduced by duct length, bends, silencers, speed controllers and other ventilation components. When selecting equipment, the resistance created by the complete extraction system should be considered rather than relying only on the fan’s unrestricted airflow figure.\u003c\/p\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the fan, filter and ducting have compatible connection diameters.\u003c\/li\u003e\n\u003cli\u003eMount the filter securely using correctly rated straps or brackets.\u003c\/li\u003e\n\u003cli\u003eConnect the filter to the extraction fan using suitable ducting or a quick-release clamp.\u003c\/li\u003e\n\u003cli\u003eSeal every connection to prevent untreated air from bypassing the filter.\u003c\/li\u003e\n\u003cli\u003eArrange the system so that air is drawn through the carbon filter before leaving the growing environment.\u003c\/li\u003e\n\u003cli\u003eCheck the entire extraction system for air leaks after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003ePre-Filter Cleaning and Maintenance\u003c\/h3\u003e\n\u003cp\u003eInspect the outer pre-filter regularly. Remove and clean it when dust begins to accumulate, following the care instructions supplied with the product. The sleeve must be completely dry before it is placed back over the carbon filter.\u003c\/p\u003e\n\u003cp\u003eActivated carbon gradually becomes saturated during use. Replace the filter when odour control noticeably declines despite correct installation, clean ducting and an appropriate airflow rate. Service life varies with humidity, temperature, contaminant levels, airflow and operating hours.\u003c\/p\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThe RAM AirTECH LITE is a passive activated carbon filter and requires a compatible extraction fan, ducting and connectors. The filter does not include an extraction fan unless purchased as part of a separate ventilation kit.\u003c\/p\u003e","brand":"HYDROGARDEN","offers":[{"title":"100mm x 200mm (250m3\/hr)","offer_id":56300769673601,"sku":null,"price":29.95,"currency_code":"GBP","in_stock":true},{"title":"125mm x 300mm (350m3\/hr)","offer_id":56300769706369,"sku":null,"price":34.95,"currency_code":"GBP","in_stock":true},{"title":"150mm x 400mm (600m3\/hr)","offer_id":56300769739137,"sku":null,"price":43.95,"currency_code":"GBP","in_stock":true},{"title":"200mm x 400mm (900m3\/hr)","offer_id":56300769771905,"sku":null,"price":67.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0565\/5370\/1536\/files\/RAMAirTECHFilters_4_8InchRange.png?v=1789816661","url":"https:\/\/steelroots.co.uk\/products\/ram-airtech-lite-carbon-filter","provider":"Steel Roots ","version":"1.0","type":"link"}